Valiant's Products

VCL-2145,
GPS/GNSS, Primary Reference Master Clock, IEEE-1588v2 PTP Grandmaster and NTP Server

GPS/GNSS Primary Reference Master Clock and PTP IEEE-1588v2 Grandmaster Clock, NTP Server (IPv4 and IPv6). Provides IRIG-B, 1PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits, 1.544Mbits GPS referenced clock outputs. OCXO and Rubidium Holdover Clock options available.

Data Sheet GPS, Primary Reference Clock

VCL-2145-D,
1+1 Redundant GPS/GNSS, Primary Reference Master Clock, IEEE-1588v2 PTP Grandmaster and NTP Server

1+1 Redundant GPS/GNSS, Primary Reference Master Clock, IEEE-1588v2 PTP Grandmaster, NTP Server (IPv4 and IPv6). Provides IRIG-B, 1 PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits, 1.544Mbits GPS referenced clock outputs. OCXO and Rubidium Holdover Clock options available.

Data Sheet1+1 Redundant GPS, Primary Reference Clock

VCL-2145-LC,
GPS Primary Reference Clock (PRC)

GPS Primary Reference Clock (PRC) provides 1 PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits with SSM, 1.544Mbits clock outputs with high stability OCXO Holdover Clock. Rubidium Clock option available.

Data SheetGPS Primary Reference Clock

VCL-2145-D,
1+1 Redundant GPS/GNSS, Primary Reference Master Clock, IEEE-1588v2 PTP Grandmaster and NTP Server

1+1 Redundant GPS/GNSS, Primary Reference Master Clock, IEEE-1588v2 PTP Grandmaster, NTP Server (IPv4 and IPv6). Provides IRIG-B, 1 PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits, 1.544Mbits GPS referenced clock outputs. OCXO and Rubidium Holdover Clock options available.

Data Sheet1+1 Redundant GPS, Primary Reference Clock

VCL-2156,
VCL-2156, NTP Time Server

The VCL-2156 NTP Time SERVER provides NTP Time and ITU-T G.811 Primary Reference Clock locked to a GPS / GNSS reference to provide time synchronization to private networks such as Railways, Metro (ticketing and platform) networks, Airports and Air-Traffic Control facilities, Electric Sub-Stations, Power Distribution and Transmission companies, Oil and Gas Utilities, ISPs and Cable TV networks, Campus networks that are required to maintain a complete isolation from public networks for security reasons.

It may be also used by 2G, 3G and LTE service providers which provide a ToD (Time-of-Day) reference to their customers over their wireless networks. Ports include GPS / GNSS Receiver, and Output ports include 2.048 MHz, 10 MHz, 50 Ohms, IRIG-B Unmodulated, 1 x IRIG-B Modulated, 1PPS, 1PPM, ToD (Time-Of-Day) output compliant to NMEA0183 (DB9, RS-232C) and IPv4 and IPv6 NTP Time Server. OCXO Oscillator is offered for Holdover Clock.

Data Sheet GPS NTP Server and PTP Grandmaster

VCL-2424
Pole Mount - PTP IEEE-1588v2 Grandmaster PRC and NTP Time Server

VCL-2424, a Pole Mount version Primary Reference Clock (PRC), IEEE-1588v2 PTP Grandmaster, NTP Time Server is a ruggedized GNSS (GPS/GLONASS), ITU-T G.811 compliant solution provides precise time and frequency reference outputs. Applications include synchronization of 2G, 3G, 4G / LTE, 5G services in harsh, un-protected, outdoor environments, such as to mobile cell towers. It may be also used by railways and metro signalling infrastructure, airports and air-traffic control facilities, solar farms, wind-farms, electric sub-stations, power distribution infrastructure, off-shore oil and gas rigs and naval vessels that are required to operate in complete isolation due to the very nature of their application, geographical location, or due to security reasons.

VCL-2424 establishes a highly accurate phase-synchronized frequency and time base by synchronizing to the GNSS (GPS/GLONASS) satellites' atomic clocks to distribute synchronized time over packet based networks including Ethernet, Carrier Ethernet, IP and IP/MPLS Networks.

VCL-2424 Input port is a GPS / GNSS Receiver and Output ports include PTP 1588v2 Grandmaster, 2.048 MHz, 10 MHz, 1PPS, ToD (Time-Of-Day) output compliant to NMEA 0183 (RJ11) and IPv4 and IPv6 GPS NTP Time Server. The OCXO Oscillator is available for Holdover Clock mode.

Data SheetPTP IEEE-1588v2 Grandmaster PRC and NTP Time Server

VCL-2424
DIN-Rail Version - PTP IEEE-1588v2 Grandmaster PRC and GPS NTP Time Server

VCL-2424, DIN-Rail Mount version Primary Reference Clock (PRC), IEEE-1588v2 PTP Grandmaster, GPS NTP Time Server is a ruggedized GNSS (GPS/GLONASS), ITU-T G.811 compliant solution to provide a highly precise time and frequency reference outputs. Applications include synchronization of 2G, 3G, 4G / LTE, 5G services in harsh environments.

It may be also used by railways and metro signalling infrastructure, airports and air-traffic control facilities, solar farms, wind-farms, electric sub-stations, power distribution infrastructure, off-shore oil and gas rigs and naval vessels that are required to operate in complete isolation due to the very nature of their application, geographical location, or due to security reasons.

VCL-2424 establishes a highly accurate phase-synchronized frequency and time base by synchronizing to the GNSS (GPS/GLONASS) satellites' atomic clocks to distribute synchronized time over packet based networks including Ethernet, Carrier Ethernet, IP and IP/MPLS Networks.

VCL-2424 establishes a highly accurate phase-synchronized frequency and time base by synchronizing to the GNSS (GPS/GLONASS) satellites' atomic clocks to distribute synchronized time over packet based networks including Ethernet, Carrier Ethernet, IP and IP/MPLS Networks. VCL-2424 Input port is a GPS / GNSS Receiver and Output ports include PTP 1588v2 Grandmaster, 2.048 MHz, 10 MHz, 1PPS, ToD (Time-Of-Day) output compliant to NMEA 0183 (RJ11) and IPv4 and IPv6 GPS NTP Time Server. The OCXO Oscillator is available for Holdover Clock mode.

Data SheetGPS NTP Server

VCL-2112,
PTP IEEE-1588v2 Slave Clock

PTP Slave Clock (IEEE-1588v2) for ToD (Time-of-Day) and Frequency Synchronization - synchronizes to PTP Grandmaster to provide IRIG-B, 1 PPS, NMEA, 1/5/10MHz, 2.048MHz, 2.048Mbits, 1.544Mbits clock outputs. OCXO Holdover.

Data Sheet PTP IEEE-1588v2 Slave Clock

VCL-2750,
PTP 1588v2 Slave Clock (DIN Rail Version)

VCL-2750, PTP 1588v2 Slave Clock (DIN Rail Version) is a high precision, high reliability time and frequency synchronization solution which can be synchronized from a IEEE-1588v2 PTP Grandmaster to provide frequency and time-of-day synchronization across a PTP network with nanosecond accuracy. Multiple 1PPS / IRIG-B Outputs are provided to synchronize local clock (time-of-day) to IEDs, as well as RTUs to a central timing source

Data Sheet ieee-1588v2-ptp-slave

IEEE 1588v2 Solutions for Stock and Currency Trading Platforms

The dictum can be applied absolutely literally to electronic trading platforms – since significant quantities of stocks and currencies are bought and sold microseconds apart at differing rates. Financial Regulators all over the world, realizing this need, are now requiring all share trading platforms to use IEEE-1588v2 technology to synchronize to a GPS / GNSS based time-source with micro-second accuracy so that buy and sell orders can be executed with precision according to their time-stamp.

VCL-MX Version 6 - 80 E1 Voice and Data Multiplexer

  • 160Mbps, 80 E1 fully non-blocking cross-connect at 64Kbps (DS-0) level (2480 DS-0 – any to any time-slot cross-connect)
  • Multi-service platform – may be used to provide a wide variety of voice and data services from single chassis
  • 1+1 E1 Link Protection / E1 Port Redundancy (8 E1's per card)
  • 1+1 Control Card Processor Redundancy
  • 1+1 Cross-Connect / TSI Redundancy
  • 1+1 Timing (Synchronization Clock) Redundancy. User selectable synchronization priority
  • 1+1 48V DC Power Supply Redundancy (Dual Power Input – allows the equipment to be powered from two separate sources
  • Provides 4 Binary (110VDC / 220VDC) Teleprotection Commands interface for Distance Protection
  • Provides IEEE C37.94 Optical Teleprotection ports for providing Distance / Differential Protection
  • Supports Automated Meter Data Reading (AMR) application with RS232 / RS485 interfaces
  • Extending Analog Breaker Status Monitoring to Audio / Visual Annunciator Panel at Remote Location.
Data Sheet VCL-MX Version 6

E1 Multiplexer - Version 5

Offers 12 x E1 non-blocking cross-connect at 64Kbps (DS-0) level with FXO, FXS, E&M (2 Wire/4 Wire), FXS-FXS (Hot-line), V.11, RS232, G.703 @ 64 Kbps, Co-Directional, Magneto, Conference interface, V.35, V.36, X.21, RS530, 10BaseT - Ethernet interfaces with Remote Management. Available with redundant 1+1 power supply. Used in a Point-to-Point, Point-to-Multi point, Add-Drop (drop-insert), Tree and Star topology. Telnet, SNMP V2, Network Management System.

Data SheetE1 Multiplexer

E1 Multiplexer - Version 3 - Deluxe

Offers FXO, FXS, E&M (2 Wire/4 Wire), FXS-FXS (Hot-line), RS232, and G.703 @ 64 Kbps, Co-Directional, V.35, V.36, X.21, RS530, 10BaseT - Ethernet interfaces, Telnet, Remote Management, SNMP, NMS.

Data Sheet (Deluxe) E1 Multiplexer

E1 Multiplexer - Version 2 - Deluxe

Offers FXO, FXS, E&M (2 Wire/4 Wire), FXS-FXS (Hot-line), RS232 and G.703 @ 64 Kbps, Co-Directional interfaces, Telnet, Remote Management, SNMP, NMS.

Data Sheet (Deluxe) E1 Multiplexer

VCL-MX Version 6 - DXC 80xE1 Digital Access Cross Connect Switch

The VCL-MX Version 6 DXC - 80 E1, 160Mbps Digital Access Cross Connect is a modular switch which may be scaled from 8 E1 Ports to up to 80 E1 Ports. The VCL-MX Version 6, E1 DACS (E1 DXC) offers full cross-connect functionality to cross-connect between 64Kbps time-slots (DS-0s), "n"x64Kbps consecutive DS-0s and Fractional E1 channels to full E1 channels.

Data Sheet VCL-MX Version 6

VCL-MX Version 6 - DXC 80xT1 Digital Access Cross Connect Switch

The VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch, is a modular switch that may be scaled from 8 T1 Ports to up to 80 T1 Ports. The VCL-MX Version 6, T1 DACS (T1 DXC) offers full cross-connect functionality to cross-connect between 64Kbps time-slots (DS-0s), “n"x64 Kbps consecutive DS-0s and Fractional T1 channels to full T1 channels.

Data Sheet VCL-MX Version 6

VCL-TP, Teleprotection over IEEE C37.94 Optical Fiber interface

VCL-TP, Teleprotection over IEEE C37.94 Optical Fiber interface equipment is an extremely rugged product has been designed to operate reliably even under the most demanding conditions and environment. The VCL-TP, Teleprotection Equipment offers up to 8, 2-way independent command channels which can be operated selectively, in a combination, or simultaneously over a C37.94 compliant optical fiber link.

VCL-TP, Teleprotection Equipment may be used independently in a point-to-point application between two nodes connected over an optical fiber link, or it may be used as an integrated part of the VCL-MX Version 6, E1 voice and data multiplexer solution over SDH or PDH data networks.

Available with:

  • IEEE C37.94 compliant Multi-Mode optical fiber interface for transmission over short-reach multi-mode optical fiber link
  • IEEE C37.94 modulation compliant Single-Mode optical fiber interface for transmission over long-reach, single-mode optical fiber link (≤ 40 KM, ≤ 80 KM, ≤ 120 KM, ≤ 150 KM, ≤ 180 KM), without optical repeaters.
Data Sheet Teleprotection Equipment

VCL-TP, Teleprotection over IEEE C37.94 (1+1 redundant) Optical Fiber interface With Trip Counter Display

VCL-TP, Teleprotection over IEEE C37.94 Optical Fiber interface is an extremely reliable and flexible product that is available with 1+1 Optical Link Redundancy (C37.94), 1+1 Power Supply and 8/16, Digital Trip Counter Display Panel with 8 user configurable External Relay Alarm output options.

VCL-TP, Teleprotection Equipment may be used independently, in a standalone point-to-point application, or as an integral extension of the VCL-MX Version 6, E1 Voice and Data Multiplexer solution to provide Teleprotection over SDH or PDH data networks.

VCL-TP, Teleprotection Equipment is extremely reliable and flexible product that offers up to 8, 2-way independent command channels, operated selectively or simultaneously over a wide choice and a variety of transmission interfaces.

Available with:

  • IEEE C37.94 compliant Multi-Mode optical fiber interface for transmission over short-reach multi-mode optical fiber link
  • IEEE C37.94 modulation compliant Single-Mode optical fiber interface for transmission over long-reach, single-mode optical fiber link (≤ 40 KM, ≤ 80 KM, ≤ 120 KM, ≤ 150 KM, ≤ 180 KM), without optical repeaters.
Data Sheet Teleprotection Equipment

VCL-TP, Teleprotection with E1, 2.048Mbps, G.703 interface over an E1 Link

VCL-TP, Teleprotection with E1, 2.048Mbps, G.703 interface over an E1 Link is an extremely rugged product has been designed to operate reliably even under the most demanding conditions and environment. The VCL-TP, Teleprotection Equipment offers up to 8, 2-way independent command channels which can be operated over an E1, 2.048Mbps, G.703 interface option for transmission over E1 links.

VCL-TP, E1 Teleprotection Equipment may be used independently in a point-to-point application between two nodes connected over an optical fiber link, or it may be used as an integrated part of the VCL-MX Version 6, E1 voice and data multiplexer solution over SDH or PDH data networks.


Data Sheet Teleprotection Equipment

VCL-TP, Teleprotection with 64Kbps, G.703 co-directional digital data interface option for transmission over 64Kbps data link

VCL-TP, Teleprotection with 64Kbps, G.703 co-directional digital data interface option for transmission over 64Kbps data link is an extremely rugged product has been designed to operate reliably even under the most demanding conditions and environment. The VCL-TP, Teleprotection Equipment offers up to 8, 2-way independent command channels which can be operated over a G.703, 64Kbps co-directional digital data link.

VCL-TP, Teleprotection Equipment may be used independently in a point-to-point application between two nodes connected over an optical fiber link, or it may be used as an integrated part of the VCL-MX Version 6, E1 voice and data multiplexer solution over SDH or PDH data networks.

Data Sheet Teleprotection Equipment

VCL-TP, Teleprotection with IEC-61850 GOOSE interface over C37.94 (Optical) / E1 interface

VCL-TP, Teleprotection with IEC-61850 GOOSE interface over C37.94 (Optical) / E1 interface is an extremely reliable and flexible product that is available with 1+1 Link Redundancy (E1 + C37.94) or (C37.94 + C37.94), 1+1 Power Supply and 8, Digital Trip Counter Display Panel with 8 user configurable External Relay Alarm extensions. 1+1 redundant protection switching / route protection is available between C37.94 optical and E1 interfaces with automatic switchover to redundant link in the event of the failure of the primary link.

VCL-TP, Teleprotection Equipment may be used independently, in a standalone point-to-point application, or as an integral extension of the VCL-MX Version 6, E1 Voice and Data Multiplexer solution to provide Teleprotection over SDH or PDH data networks.

Data Sheet Teleprotection Equipment

VCL-TP, IEC 61850 GOOSE over IP / MPLS

The VCL-TP Teleprotection - IEC-61850 GOOSE over IP/MPLS equipment is a compact, 1U high, 19-inch rack mountable equipment that is designed transport IEC-61850 GOOSE* messages over a routable IP/MPLS network. (*Generic Object Oriented Substation Event.)

VCL-TP is designed to transmit / receive the IEC-61850 compliant “Digital Substations” to provide “Distance Protection” over IP / MPLS links using IEC-61850 GOOSE messages instead of “Binary” commands.

VCL-TP Teleprotection - IEC-61850 GOOSE over IP/MPLS incorporates the same level of “reliability” and “dependability” that the users have come to expect of the IEEE C37.94 based communication interface. Additionally, the VCL-TP Teleprotection - IEC-61850 GOOSE over IP/MPLS provides un-paralleled security, speed as well as all the advantages of an IEC-61850 GOOSE based system operating in a “Digital Sub-station” environment.

Data Sheet Teleprotection Equipment

Teleprotection over IP/MPLS – 10/100BaseT (Electrical) or 100BaseFX (Optical) Ethernet Interface to provide Teleprotection over IP/MPLS link

VCL-TP, Teleprotection over IP/MPLS – 10/100BaseT (Electrical) or 100BaseFX (Optical) Ethernet Interface incorporates the same level of “reliability” and “dependability” that the users have come to expect of the C37.94 based communication interface. Additionally, the VCL-TP, Teleprotection over IP / MPLS Equipment provides un-paralleled security, speed as well as all the advantages of operating in a “Digital Sub-station” environment.

Available with:

  • 10/100BaseT (Electrical) Interface to provide Teleprotection over IP/MPLS link.
  • 100BaseFX (Optical) Ethernet Interface to provide Teleprotection over IP/MPLS link.
Data Sheet Teleprotection Equipment

VCL-2707, IEEE C37.94 to T1 converters

VCL-2707, IEEE C37.94 to T1 Converter is a ruggedized and robust, sub-station-hardened protocol converter that converts IEEE C37.94 Interface to a T1 Interface, and vice-versa. The VCL-2707 is designed for use in point-to-point applications.

The most common application for the VCL-2707 converter is for augmenting legacy IEEE C37.94 data transmission over a T1 network between two sub-stations. By installing a VCL-2707 converter, the existing IEEE C37.94 interfaces from protection relays can be transmitted over the T1 network without incurring large capex, or without the tiresome task of having to replace or rewire the IEEE C37.94 Relays which need to be interconnected to the far end substations over T1 (SONET) transmission links.

  • Number of C37.94 interfaces per card: 1 Tx, 1 Rx
  • Number of interfaces: 1 T1 (1.544 Mbit/s) interfaces
Data Sheet Teleprotection Equipment

VCL-2709, IEEE C37.94 to E1 Converter

VCL-2709, IEEE C37.94 to E1 Converter is a ruggedized and robust, sub-station-hardened protocol converter that converts IEEE C37.94 data to E1 data. VCL-2709 supports point-to-point applications.

The most common application for the VCL-2709 converter is for augmenting legacy IEEE C37.94 data transmission over an E1 network between two sub-stations. By installing a VCL-2709 converter, the existing IEEE C37.94 interfaces from protection relays can be transmitted over the E1 network without incurring large capex, or without the tiresome task of having to replace or rewire the IEEE C37.94 Relays which need to be interconnected to the far end substations over E1 (SDH) transmission links.

  • Number of C37.94 interfaces per card: 1 Tx, 1 Rx
  • Number of interfaces: 1 E1 (2.048 Mbit/s) Interface (Electrical G.703)
Data Sheet IEEE C37.94 to E1 Converter

VCL-2710, C37.94 to Optical Converter

VCL-2710, IEEE C37.94 to Optical Converter / C37.94 Optical Repeater is a ruggedized, sub-station-hardened converter that converts IEEE C37.94 Multi-Mode signal to Optical Single-Mode Optical signal. The equipment is designed to extend IEEE C37.94 multi-mode signals over extended single-mode optical fiber spans. The VCL-2710, IEEE C37.94 to Optical Converter includes the clock synchronization and clock re-generation functions which allows it to transmit the IEEE C37.94 multi-mode signal over very long single-mode optical fiber links of up to 90 Miles / 150 Kms. VCL-2710 is designed for use in point-to-point applications. The VCL-2710 meets and complies with the IEC-61850-3, EMI, EMC, Surge and Temperature specifications making it suitable for sub-station installations to provide uninterrupted service even in the most demanding and harsh environments.

Data Sheet IEEE C37.94 to Optical Converter

VCL-2711, IEEE C37.94 over IP / MPLS / Ethernet Transmission Equipment

VCL-2711, IEEE C37.94 over IP / MPLS / Ethernet Transmission Equipment is a ruggedized, robust and sub-station-hardened transmission equipment which converts and transmits up to two IEEE C37.94 Interfaces over an Ethernet / IP / MPLS-TP or MPML-IP link with “SDH / SONET like” performance. The far-end VCL-2711 unit receives the Ethernet data stream and re-converts it back to the IEEE C37.94 Interfaces. The VCL-2711 units must be always used in pairs, with one unit installed on each end of the Ethernet / IP / MPLS link.

Data Sheet IEEE C37.94 to Optical Converter

VCL-MX, Gigabit Ethernet Voice and Data Multiplexer

VCL-MX, Gigabit Ethernet, Voice & Data Multiplexer may be used to provide legacy Voice, Data and C37.94 Teleprotection Channels over Gigabit Ethernet / IP / MPLS networks with Stratum level timing precision. The VCL-MX, IP Multiplexer uses IEEE-1588v2 PTP synchronization technology to provide time-of-day and frequency synchronization to a single central GPS source with 0.5 micro-second (500 nanosecond) accuracy.

Data Sheet VCL-MX-IP

VCL-5000: Firewall, Router and Encryption Equipment

Valiant’s VCL-5000 is an integrated router and firewall equipment with extremely advanced features that may be installed to secure critical infrastructure such as Sub-Stations, Smart Grid Distribution Systems, Airport and Railway IT Networks as well as Financial Infrastructure such as Banks and Payment Processing Gateways.

Access to VCL-5000 is password protected with advanced firewall capabilities that meet and exceed NERC as well as all mandatory requirements of Password Protection and Control as provided in the GR-815-CORE-2 specifications.

Data Sheet Firewall, Router and Encryption

Enigmätron-C, Data Encryption, Router and Firewall Equipment

Valiant’s Enigmätron-C is an integrated router, firewall and data encryption equipment with extremely advanced features that may be installed to secure critical infrastructure such as Sub-Stations, Smart Grid Distribution Systems, Airport and Railway IT Networks as well as Financial Infrastructure such as Banks and Payment Processing Gateways.

The Enigmätron-C may also be installed in centrally managed networks consisting of multiple branch offices and edge locations to provide secure communications between ATMs, Point-Of-Sale Terminals and their corresponding back-end Central Servers.

Data Sheet Enigmätron-C

Enigmätron Firewall Equipment

Valiant’s Enigmätron is an integrated router and firewall equipment with extremely advanced firewall features that may be installed to secure critical infrastructure such as Sub-Stations, Smart Grid Distribution Systems, Airport and Railway IT Networks as well as Financial Infrastructure such as Banks and Payment Processing Gateways.

Access to Enigmätron is password protected with advanced firewall capabilities that meet and exceed NERC as well as all mandatory requirements of Password Protection and Control as provided in the GR-815-CORE-2 specifications. Enigmätron can optionally be managed centrally from a RADIUS Server to provide enhanced levels of access security and centralized password management and control.

Data Sheet Enigmätron Firewall Equipment

VCL-Xcöde: IEC 60870-5-104 and DNP Protocol Encryptor

Valiant's VCL-Xcöde is an integrated IEC 60870-5-104 and DNP Data Encryption Equipment with extremely advanced features that may be installed to secure and protect RTU data in critical infrastructure such as Sub-Stations, Smart Grid Distribution Systems, Oil and Gas Infrastructure and Railway Signalling Networks from being compromised or accessed by hostile elements.

The VCL-Xcöde may be installed in point-to-point or point-to-multi-point applications in centrally managed networks consisting of multiple edge locations to provide secure communications between multiple RTU Terminals and their corresponding IEC 60870-5-104 and DNP central server(s) located in Load Dispatch Centre(s) / SCADA Management Centre(s) and Rail Traffic Control Room(s). Additionally, the VCL-Xcöde also protects the RTUs against hostile network attacks and intrusions arising out of Denial of Service (DoS) attacks and MitM (Man-In-the-Middle).

Data Sheet IEC 60870-5-104 and DNP Protocol Encryptor

VCL-2143, MouseTrap™ IP Network Intrusion Detector

Valiant's MouseTrap™ is an essential security tool that acts like a decoy server, or sits behind the firewall equipment in a secure environment to detect firewall breaches and unauthorized intrusions. Valiant's MouseTrap™ forms an essential part of the digital forensics kit that may be installed in secure critical infrastructure such as in Sub-Stations, Smart Grid Distribution Systems, Airport and Railway IT Networks, as well as Financial Infrastructure such as Banks and Payment Processing Gateways to “alert” the network administrator of unauthorized intrusions or a firewall breach.

Data Sheet MouseTrap

VCL-2457, Smart Rack Management Unit

Valiant's VCL-2457, Rack Management and Fan Control Unit is designed to convert and transform ordinary racks into “Smart Racks”.

The VCL-2457, Smart Rack Management Unit provides the following options:

  • Designed to monitor and control the ambient temperature of an equipment rack by “switching on” / “switching off” according to the user desired thermal environment in the equipment rack.
  • “6” binary I/Os (DIOs) for sensing open loop / closed loop conditions. These I/Os may be used to connect to door open alarm, smoke alarm, fire alarm, or used to connect to dry-contact relays that are normally provided on other electronic equipment that is installed in the racks to provide alarms that are indicative of equipment failure.
  • “4” 4-20mA inputs (AIOs) that may be used to connect to external (third party) sensors to sense humidity etc.
  • “2” 0-5Volt inputs (AIOs) that may be used to connect to external (third party) sensors to read the voltage levels of backup battery banks etc.

Data Sheet Rack Management and Fan Control Unit

VCL-E1oP (2E1 Port with PTP IEEE-1588v2 Version)

VCL-E1oP' E1 over Packet (2 E1 Port PTP IEEE-1588v2 Version) TDM over IP equipment supports transmission of up to 2 x E1 links over IP / Ethernet, MEF or MPLS networks and synchronization using PTP IEEE-1588v2 protocol. The 'VCL-E1oP' E1 over Packet (2 E1 Port PTP IEEE-1588 Version2) TDM over IP equipment with IEEE-1588v2 protocol engine which provides a highly reliable clock recovery mechanism for extremely low jitter and wander control, even under variable network conditions.

Technical Specifications
Data Sheet 2E1 Port IEEE-1588 Version

VCL-E1oP (8E1 Port with PTP IEEE-1588v2 Version)

VCL-E1oP' E1 over Packet (8 E1 Port PTP IEEE-1588v2 Version) TDM over IP equipment supports transmission of up to 8 x E1 links over IP / Ethernet, MEF or MPLS networks and synchronization using PTP IEEE-1588v2 protocol. The 'VCL-E1oP' E1 over Packet (8 E1 Port with PTP IEEE-1588v2 Version) TDM over IP equipment with PTP IEEE-1588v2 protocol engine which provides a highly reliable clock recovery mechanism for extremely low jitter and wander control, even under variable network conditions.

Technical Specifications
Data Sheet 8E1 Port IEEE-1588 Version

VCL-T1oP (2T1 Port with PTP IEEE-1588v2 Version)

'VCL-T1oP' T1 over Packet (2 T1 Port PTP IEEE-1588v2 Version) TDM over IP equipment supports transmission of up to 2 x T1 links over IP / Ethernet, MEF or MPLS networks and synchronization using PTP IEEE-1588v2 protocol. The 'VCL-T1oP' T1 over Packet (2 T1 Port PTP IEEE-1588v2 Version) TDM over IP equipment with PTP IEEE-1588 protocol engine which provides a highly reliable clock recovery mechanism for extremely low jitter and wander control, even under variable network conditions.

Technical Specifications
Data Sheet 2T1 Port IEEE-1588 Version

VCL-T1oP (8T1 Port with PTP IEEE-1588v2 Version)

'VCL-T1oP' T1 over Packet (8 T1 Port with PTP IEEE-1588v2 Version) TDM over IP equipment supports transmission of up to 8 x T1 links over IP / Ethernet, MEF or MPLS networks and synchronization using PTP IEEE-1588v2 protocol. The 'VCL-T1oP' T1 over Packet (8 T1 Port PTP IEEE-1588v2 Version) TDM over IP equipment with PTP IEEE-1588 protocol engine which provides a highly reliable clock recovery mechanism for extremely low jitter and wander control, even under variable network conditions.

Technical Specifications
Data Sheet 8T1 Port IEEE-1588 Version

VCL-E1oP (2E1 Port FE) TDM over IP / Ethernet / Packet

'VCL-E1oP' E1 over IP/Ethernet/Packet (2 E1 Port FE Version) equipment supports transmission of up to 2 x E1 links over IP / Ethernet, MEF or MPLS networks. Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional E1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 2E1 Port FE

VCL-E1oP (2E1 Port GE) TDM over IP / Ethernet / Packet

'VCL-E1oP' E1 over IP/Ethernet/Packet (2 E1 Port GE Version) equipment supports transmission of up to 2 x E1 links over IP / Ethernet, MEF or MPLS networks. Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional E1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 2E1 Port GE

VCL-E1oP (4E1 Port FE) TDM over IP / Ethernet / Packet

'VCL-E1oP' E1 over IP/Ethernet/Packet (4 E1 Port FE Version) equipment supports transmission of up to 4 x E1 links over IP / Ethernet, MEF or MPLS networks. Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional E1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 4E1 Port FE

VCL-E1oP (8E1 Port GE) TDM over IP / Ethernet / Packet

'VCL-E1oP' E1 over IP/Ethernet/Packet (8 E1 Port GE Version) equipment supports transmission of up to 8 x E1 links over IP / Ethernet, MEF or MPLS networks. Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional E1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 8E1 Port GE

VCL-E1oP (16E1 Port GE) TDM over IP / Ethernet / Packet

'VCL-E1oP' E1 over IP/Ethernet/Packet (16 E1 Port GE Version) equipment supports transmission of up to 16 x E1 links over IP / Ethernet, MEF or MPLS networks. Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional E1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 16E1 Port GE

VCL-E1oP (32E1 Port GE) TDM over IP / Ethernet / Packet

'VCL-E1oP' E1 over IP/Ethernet/Packet (32 E1 Port GE Version) equipment supports transmission of up to 32 x E1 links over IP / Ethernet, MEF or MPLS networks. Multiple units of the 32 E1 Port GE Version equipment may be cascaded to support 32 E1 Ports aggregation at the Central Office / MSC (Mobile Switching Center). Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional E1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 32E1 Port GE

VCL-T1oP (2T1 Port FE) TDM over IP / Ethernet / Packet

'VCL-T1oP' T1 over IP/Ethernet/Packet (2 T1 Port FE Version) equipment supports transmission of up to 2 x T1 links over IP / Ethernet, MEF or MPLS networks. Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional T1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 2T1 Port FE

VCL-T1oP (2T1 Port GE) TDM over IP / Ethernet / Packet

'VCL-T1oP' T1 over IP/Ethernet/Packet (2 T1 Port GE Version) equipment supports transmission of up to 2 x T1 links over IP / Ethernet, MEF or MPLS networks. Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional T1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 2T1 Port GE

VCL-T1oP (4T1 Port FE) TDM over IP / Ethernet / Packet

'VCL-T1oP' T1 over IP/Ethernet/Packet (4 T1 Port FE Version) equipment supports transmission of up to 4 x T1 links over IP / Ethernet, MEF or MPLS networks. Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional T1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 4T1 Port FE

VCL-T1oP (8T1 Port GE) TDM over IP / Ethernet / Packet

'VCL-T1oP' T1 over IP/Ethernet/Packet (8 T1 Port GE Version) equipment supports transmission of up to 8 x T1 links over IP / Ethernet, MEF or MPLS networks. Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional T1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 8T1 Port GE

VCL-T1oP (16T1 Port GE) TDM over IP / Ethernet / Packet

'VCL-T1oP' T1 over IP/Ethernet/Packet (16 T1 Port GE Version) equipment supports transmission of up to 16 x T1 links over IP / Ethernet, MEF or MPLS networks. Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional T1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 16T1 Port GE

VCL-T1oP (32T1 Port GE) TDM over IP / Ethernet / Packet

'VCL-T1oP' T1 over IP/Ethernet/Packet (32 T1 Port GE Version) equipment supports transmission of up to 32 x T1 links over IP / Ethernet, MEF or MPLS networks. Multiple units of the 32 E1 Port GE Version equipment may be cascaded to support 32 T1 Ports aggregation at the Central Office / MSC (Mobile Switching Center). Supports Circuit Emulation / CESoPSN, SAToP, MPLS, MEF, PWE3 (pseudo-wire), Fractional T1, point-to-multipoint drop and insert applications.

Technical Specifications
Data Sheet 32T1 Port GE

VCL-DS3oP - DS3 over IP/Ethernet / T3 over IP/Ethernet

'VCL-DS3oP', DS3 (T3) over IP / Ethernet equipment provides transmission of one, point-to-point, DS3 (T3) link over an IP / Ethernet, MEF or MPLS network. The 'VCL-DS3oP', DS3 (T3) over IP / Ethernet equipment is powered by a powerful PowerPC 400 MHz Processor which provides a highly reliable clock recovery mechanism for low jitter and wander control, even under variable network conditions.

Technical Specifications
Data Sheet VCL-DS3oP - DS3 / T3 over IP

VCL-E3oP - E3 over IP/Ethernet

'VCL-E3oP' (E3 over IP/Ethernet) equipment is used to transport a single E3 interface over an IP, MPLS or Ethernet network. The VCL-E3oP' (E3 over IP) equipment, is equipped with a powerful PowerPC 400 MHz Processor which provides a highly reliable clock recovery mechanism for low jitter and wander control, even under variable network conditions.

Technical Specifications
Data Sheet VCL-E3oP - E3 over IP

Gigabit Ethernet over SDH (STM-4) Converter

Gigabit Ethernet over SDH (STM-4) Equipment is a compact and high-performance Gigabit Ethernet to STM-4 converter (with VLAN TAG function), which offers three Gigabit Ethernet interfaces (2 Electrical and 1 Optical Ethernet interfaces) and 2 x STM-4 interfaces.
Gigabit Ethernet over SDH (STM-4) – Available bandwidth on a single Ethernet port on an STM-4 link is 622Mbps (up to 1000Mbps on 2 x bonded STM-4 links).

Data Sheet Gigabit Ethernet over SDH

Gigabit Ethernet over SDH (STM-1) Converters

Gigabit Ethernet over SDH (STM-1) provides a simple, cost effective and compact solution to convert 10/100/1000Base-T (Gigabit) data interface on the user side and transport Ethernet traffic over a STM-1 (155Mbps) SDH link and reconstruct the data back to ethernet frame format, at remote end. The converter is an effective method for converting and transporting 10/100/1000Base-T (Gigabit) ethernet data over an STM-1 (155Mbps) SDH link.
Gigabit Ethernet over SDH (STM-1) – Available bandwidth on a single Ethernet port on an STM-1 link is 137Mbps.

Data Sheet Gigabit Ethernet over SDH

Ethernet over SDH (STM-1) Converters

Ethernet over SDH / STM-1 (EoS) provides a simple, cost effective and compact solution to convert 10/100BaseT data interface on the user side and transport Ethernet traffic over a STM-1 SDH link and reconstruct the data back to ethernet frame format, at remote end. The converter is an effective method for converting and transporting 10/100BaseT ethernet data over an STM-1 (SDH) link.
Ethernet over SDH (STM-1) – Available bandwidth on four Ethernet ports (4VCG) on an STM-1 link (126Mbps bandwidth aggregated on 4 Ethernet ports).

Data SheetEthernet over SDH

Ethernet over DS3 converters

Valiant offers its Ethernet over DS3 Switch (Ethernet to DS3 Switch) packaged in a 1U, 19-inch rack-mountable chassis. Valiant Ethernet over DS3 Switch (Ethernet over DS3 Switch) provides a four 100BaseT Ethernet and 100Base-FX optical (optional) ethernet interfaces on the user side which may be used to transport Ethernet traffic over a DS3 link. Both ethernet interfaces may be used simultaneously. The Switch provides a simple and cost effective method to convert and transport ethernet data over an DS3 link.

Data Sheet Ethernet over DS3 converters

Ethernet over E3 converters

Valiant offers its Ethernet to E3 converters (Ethernet over E3 Converters) packaged in a 19-inch rack-mountable chassis. Provides framed and un-framed E3 options. Valiant Ethernet to E3 converters (Ethernet over E3 Converters) provides a 100BaseT data interface on the user side which may be used to transport Ethernet traffic over a E3 link. The converter provides a simple and cost effective method to convert and transport 100BaseT ethernet data over a E3 link.

Data SheetEthernet over E3 converters

Ethernet over 8/16 E1 - ML-PPP

VCL-ETH-8E1-ML / VCL-ETH-16E1-ML Converter allows the user to send Ethernet data between two points or between multiple points (maximum 12 directions), over 8/16 E1 Links respectively. E1 Interfaces options are 75 Ohms/120 Ohms.

Data Sheet Ethernet over 8/16 E1

Ethernet over 1 E1

Converts 1 x 10Base-T Ethernet (electrical) interface to 1 x G.703 E1 (or fractional E1) interface. (Standard Version).

Data Sheet Ethernet over 1 E1

4 Ethernet over E1

Converts and transports upto 4 x Ethernet links over 1 E1 link in a shared mode, or a discreet mode. (Standard Version).

Data Sheet 4 Ethernet over E1

4 Ethernet over T1

4 x Ethernet over T1 (IP over TDM) package in a 1U High, 19-inch rack-mountable chassis. It provides four 10/100BaseT (4 RJ-45) data interfaces on the user side which may be used to transport Ethernet traffic over a T1 link.

Data Sheet 4 Ethernet over T1

Ethernet over 4 E1

Converts 4 x 10Base-T Ethernet (electrical/optical) interface to 4 x E1s G.703 (or fractional E1s) interfaces. SNMP / CLI / GUI management. (Deluxe Version).

Data Sheet Ethernet over 4 E1

Ethernet over 8 E1

Converts 4 x 10Base-T Ethernet (electrical/optical) interface to 8 x E1s G.703 (or fractional E1s) interfaces. SNMP / CLI / GUI management. (Deluxe Version).

Data Sheet Ethernet over 8 E1

Ethernet over 16 E1

Converts 4 x 10Base-T Ethernet (electrical/optical) interface to 16 x E1s G.703 (or fractional E1s) interfaces. SNMP / CLI / GUI management. (Deluxe Version).

Data Sheet Ethernet over 16 E1

SDH / STM-1 Optical to SDH / STM-1 Electrical converters

Valiant Communications offers STM-1 Optical to STM-1 Electrical converter provides a simple and cost-effective conversion between STM-1 optical interface and STM-1 electrical interface. STM-1 Optical to STM-1 Electrical converter is an interface conversion equipment supplied with one STM-1 electrical (75 Ohms BNC) interface and one STM-1 optical (MSA compliant SFP) interface.

1+1, STM-1 Optical to STM-1 Electrical converter option is also offered and available.

STM-1 Optical to STM-1 Electrical converter is a compact solution housed in a 1U high (44mm), 19-inch rack-mountable shelf, which can be installed in any DIN-standard 19-inch rack.

Data Sheet STM-1

VCL-1400, STM-16 / 64 SDH Multiplexer

Valiant offers VCL-1400 STM-1, STM-4, STM-16 and STM-64 SDH Multiplexers with MPLS-TP with 1+1 Redundancy of Controller Card, Cross-Connect, E1, Optical options. Supported 1+1 MSPP, SNCP, Packet Switch support. XC capacity from 2.5G, 5G, 10G, 20G, 60G. The VCL-1400 is a compact POTP platform which is targeted for deployment in the edge and access part of a transport network. It can be configured both as a TDM MSPP, as well as a Packet Switch. It supports both TDM and Ethernet as Line Interfaces. It offers full redundancy and comes with an expansion chassis for deployment in high drop locations. STM-16 and STM-64 SDH Multiplexer (up to 60G) offers TDM MSPP and Packet Switch support. Supports TDM and Ethernet as Line Interfaces. It offers full redundancy and comes with an expansion chassis.

  • POTP Evolution: SDH, OTN & Ethernet Based line Interfaces
  • High Capacity Micro POTP: 1U to 4U
  • Packet Switching: High Capacity ranging from 2.5G, 5G, 10G, 15G, 20G and 60G Packet Fabric
  • MPLS-TP: Traffic Engineered Pseudo-wire
  • 50ms Protection on packet: ELPS, ERPS
  • Circuit Emulation: TDM over Packet
  • TDM Switching: High capacity 60G LO Fabric for efficient transport of SDH & PDH
  • Packet Synchronization

Data Sheet STM-16 / 64 SDH Multiplexer

VCL1400P: E1 / SDH Packet Transport Network (PTN)

VCL-1400P: E1 / SDH Packet Transport Network (PTN) is a compact packet aggregation solution which is well suited for deployment in the edge and access part of a packet transport network. It supports full PTN feature set enabling a service provider to provide end-to-end pseudo-wire and Ethernet multipoint services.

VCL1400P can serve as a cell-site transport network element back hauling 4G services and can be used to build aggregation rings of 10 Gbps. It can be used to provide GigE enterprise services and L2 VPN services with advanced QoS support. VCL1400P is available in different factory fitted configurations.

Available in two (2) version:

VCL1400-P Model C:

19”, 1U high Packet Transport System with

  • 8xGE optical (SFP based / without SFPs),
  • 8xGE Electrical ports and 16xE1 + 4xSTM-1 CEM.
  • Supports separate redundant FRU and redundant front -48V DC PSU cards.

VCL1400-P Model D:

19”, 1U high Packet Transport System with

  • 8xGE optical (SFP based / without SFPs),
  • 8xGE Electrical ports, 16xE1 + 4xSTM-1 CEM &
  • 4x1G/10G optical (SFP based / without SFPs) Ports.
  • Supports separate redundant FRU and redundant front -48V DC PSU cards.

Data Sheet STM-16 / 64 SDH Multiplexer

VCL-1400, SONET Multiplexer with MPLS-TP

The VCL-1400 is an ultra-compact, carrier class, and cost effective family of micro packet optical Equipment (micro POTP) designed to manage and deliver services from the optical core to the access. The VCL-1400 can be configured as a Terminal Multiplexer (TMUX), Add-Drop Multiplexer (ADM) and In-Line Amplifier or as stand-alone Cross-Connect for SONET applications, as well as for Packet and Packet Aggregation applications.

VCL-1400, OC-3/12/48/192 and GE/10GE platform, has been envisaged to address the growing demand for an ultra-compact SONET OC-3/12/48/192 Add-drop Multiplexer (ADM) , GE and 10GE CPE and aggregation and provide Ethernet-over-SONET mapping and layer 2 switching functions, including Link Capacity Adjustment Scheme (LCAS) with Virtual Concatenation (VCAT).

VCL-1400 supports OC-3/12/48/192 aggregate interfaces, T1 interface cards, E3/DS3 and Ethernet/Fast Ethernet/Gigabit Ethernet and 10 Gigabit Ethernet interfaces. It can be configured in linear, ring and bus topologies.

Data Sheet STM-16 / 64 SDH Multiplexer

VCL1400P: T1 / SONET Packet Transport Network (PTN)

VCL1400P is a compact packet aggregation solution which is well suited for deployment in the edge and access part of a packet transport network. It supports full PTN feature set enabling a service provider to provide end-to-end pseudo-wire and Ethernet multipoint services.

VCL1400P can serve as a cell-site transport network element back hauling 4G services and can be used to build aggregation rings of 10 Gbps. It can be used to provide GigE enterprise services and L2 VPN services with advanced QoS support. VCL1400P is available in different factory fitted configurations.

Available in two (2) version:

VCL1400-P Model C:

19”, 1U high Packet Transport System with

  • 8xGE optical (SFP based / without SFPs),
  • 8xGE Electrical ports & 16xDS1 + 4xOC-3 CEM.
  • Supports separate redundant FRU and redundant front -48V DC PSU cards.

VCL1400-P Model D:

19”, 1U high Packet Transport System with

  • 8xGE optical (SFP based / without SFPs),
  • 8xGE Electrical ports,
  • 16xDS1 + 4xOC-3 CEM and 4x1G/10G optical (SFP based / without SFPs) Ports.
  • Supports separate redundant FRU and redundant front -48V DC PSU cards.

Data Sheet STM-16 / 64 SDH Multiplexer

STM-1, 63 E1 (Optical / Electrical) Add-Drop SDH Multiplexer

Valiant offers STM-1 63 E1 (Optical / Electrical), Add-Drop SDH Multiplexer unit is a modular platform unit with two 155.52Mbps optical / electrical interfaces, which may be used in a point-to-point, chain or ring application to provide an ultra-compact, cost effective and flexible multi-service platform.

Data Sheet STM-1, 63 E1 (Optical / Electrical) Add-Drop SDH Multiplexer

STM-1 (Optical / Electrical) Add-Drop Multiplexer (with upto 16 E1 & 4 Ethernet) SDH Equipment

Valiant offers STM-1 (Optical / Electrical), E1 and Ethernet Multi-Service SDH Transmission Unit is a modular platform unit with two 155.52Mbps optical / electrical interfaces, which may be used in a point-to-point, chain or ring application to provide an ultra-compact, cost effective and flexible multi-service platform.

Data Sheet STM-1 (Optical / Electrical) Add-Drop Multiplexer

STM-1/4 and STM-16 SDH ADM Multiplexer

STM-1/4 and STM-16 Add-Drop Multiplexer with 256E1, E3, DS3, STM-1e/1o, STM-4 and 10/100Mbps and GigE Ethernet interfaces at STM-16 rates. Full redundancy. Configurable to STM-1/STM-4. Upgragable to STM-16.
Tributary Interfaces

  • 28 x E1
  • 63 x E1
  • 3 x E3/DS3
  • 2 x STM-1 (S1.1, L1.1, L1.2)
  • 8 x 10/100Base-T Ethernet
  • 2 x GigE Transport card
  • 8 x 10/100 Base-T and 2 x GigE switching card

Data Sheet STM-16 SDH ADM Multiplexer

SDH / STM-1 Optical to SDH / STM-1 Electrical converters

Valiant Communications offers STM-1 Optical to STM-1 Electrical converter provides a simple and cost-effective conversion between STM-1 optical interface and STM-1 electrical interface. STM-1 Optical to STM-1 Electrical converter is an interface conversion equipment supplied with one STM-1 electrical (75 Ohms BNC) interface and one STM-1 optical (MSA compliant SFP) interface.

1+1, STM-1 Optical to STM-1 Electrical converter option is also offered and available.

STM-1 Optical to STM-1 Electrical converter is a compact solution housed in a 1U high (44mm), 19-inch rack-mountable shelf, which can be installed in any DIN-standard 19-inch rack.

Data Sheet SDH / STM-1 Optical to SDH / STM-1 Electrical converters

VCL-1400, STM-16 / 64 SDH Multiplexer

Valiant offers VCL-1400 STM-1, STM-4, STM-16 and STM-64 SDH Multiplexers with MPLS-TP with 1+1 Redundancy of Controller Card, Cross-Connect, E1, Optical options. Supported 1+1 MSPP, SNCP, Packet Switch support. XC capacity from 2.5G, 5G, 10G, 20G, 60G. The VCL-1400 is a compact POTP platform which is targeted for deployment in the edge and access part of a transport network. It can be configured both as a TDM MSPP, as well as a Packet Switch. It supports both TDM and Ethernet as Line Interfaces. It offers full redundancy and comes with an expansion chassis for deployment in high drop locations. STM-16 and STM-64 SDH Multiplexer (up to 60G) offers TDM MSPP and Packet Switch support. Supports TDM and Ethernet as Line Interfaces. It offers full redundancy and comes with an expansion chassis.

  • POTP Evolution: SDH, OTN & Ethernet Based line Interfaces
  • High Capacity Micro POTP: 1U to 4U
  • Packet Switching: High Capacity ranging from 2.5G, 5G, 10G, 15G, 20G and 60G Packet Fabric
  • MPLS-TP: Traffic Engineered Pseudo-wire
  • 50ms Protection on packet: ELPS, ERPS
  • Circuit Emulation: TDM over Packet
  • TDM Switching: High capacity 60G LO Fabric for efficient transport of SDH & PDH
  • Packet Synchronization
Data Sheet STM-16 / 64 SDH Multiplexer

4 E1 Optical Multiplexer plus Ethernet with SNMP

4 E1 Optical Multiplexer with 100Mbps Ethernet data transmission rate solution is a high performance optical line transmission equipment, combines 4, ITU-T G.703 compliant standard electrical E1s plus 100Mbps ethernet signal into an optical data stream for transport over fiber optic pairs.

Data Sheet 4 E1 Optical Multiplexer plus Ethernet with SNMP

8 E1 Optical Multiplexer plus Ethernet with SNMP

8 E1 Optical Multiplexer with 100Mbps Ethernet data transmission rate solution is a high performance optical line transmission equipment, combines 8, ITU-T G.703 compliant standard electrical E1s plus 100Mbps ethernet signal into an optical data stream for transport over fiber optic pairs.

Data Sheet 8 E1 Optical Multiplexer plus Ethernet with SNMP

16 E1 with Gigabit Ethernet (Wire Speed) Optical Multiplexer

High performance optical line transmission equipment combines 16 ITU-T G.703 compliant standard electrical E1, 2.048Mbps signals into an optical data stream for transport over fiber optic cables, plus 10/100Mbps Ethernet port. 850nm / 1310nm / 1550nm transmitter options available. 1+1 Optical Redundancy (Protection Switching) available.

Data Sheet 16 E1 with Gigabit Ethernet (Wire Speed) Optical Multiplexer

Gigabit Optical Add-Drop Multiplexer

Gigabit Optical Add-Drop Multiplexer is a unique Gigabit multi-service optical fiber transport solution which transmits both Gigabit Ethernet (Gigabit Wire-Speed) data along with upto 16 E1 (TDM) channels over an optical fiber link. This product provides up to 4 x Gigabit interfaces with rate-limiting option on each port (with user selectable bandwidth allocation on each Gigabit port).

Data Sheet Gigabit Optical Add-Drop Multiplexer

VCL-SafeComm Protection Switching

VCL-Safecomm-E, 1+1 Automatic Ethernet Protection / Ethernet Failover / AB Fallback Switch

VCL-SafeComm-E is a family of Ethernet Failover Protection Switches that provide 1+1 Automatic Ethernet Failover / AB Fallback Protection between an "active” and "standby" equipment; or between “main” and “standby” networks which are connected to the network through an Ethernet interface.

VCL-SafeComm-E is available in 3 versions:

Data Sheet VCL-Safecomm-E

8 E1 Links (24 E1 Ports) Protection Switching (APS)

Used to protect upto 8 E1 Links (24 E1 Ports), point-to-point links and provide an alternate communication route to each E1 Link between any two E1 points, in the event of the failure of the primary (Main) E1 communication route. The equipment is “Fail-Safe” and never becomes a point-of-failure, even in power down condition.

Data Sheet 8 E1 Links (24 E1 Ports) Protection Switching

16 E1 Links (48 E1 Ports) Protection Switching (APS)

Used to protect upto 16 E1 Links (48 E1 Ports), point-to-point links and provide an alternate communication route to each E1 Link between any two E1 points, in the event of the failure of the primary (Main) E1 communication route. The equipment is “Fail-Safe” and never becomes a point-of-failure, even in power down condition.

Data Sheet 16 E1 Links (48 E1 Ports) Protection Switching

8 T1 Links (24 T1 Ports) Protection Switching (APS)

Used to protect upto 8 T1 Links (24 T1 Ports), point-to-point links and provide an alternate communication route to each T1 Link between any two T1 points, in the event of the failure of the primary (Main) T1 communication route. The equipment is “Fail-Safe” and never becomes a point-of-failure, even in power down condition.

Data Sheet 8 T1 Links (24 T1 Ports) Protection Switching

16 T1 Links (48 T1 Ports) Protection Switching (APS)

Used to protect upto 16 T1 Links (48 T1 Ports), point-to-point links and provide an alternate communication route to each T1 Link between any two T1 points, in the event of the failure of the primary (Main) T1 communication route. The equipment is “Fail-Safe” and never becomes a point-of-failure, even in power down condition.

Data Sheet 16 T1 Links (48 T1 Ports) Protection Switching

Protection (Failover) Switch

E1 Protection (Failover) Switch

12 Port E1 (4 E1 Links) Automatic Protection (Fail-Over) Switch allows the user to connect upto four E1 lines from the telephone company to "active", as well as to "standby" terminal(s), such as data servers / routers etc. at the customer premises. The equipment is “Fail-Safe” and never becomes a point-of-failure, even in power down condition.

Data Sheet E1 Protection (Failover) Switch

T1 Protection (Failover) Switch

12 Port T1 (4 T1 Links) Protection (Fail-Over) Switch allows the user to connect upto four T1 lines from the telephone company to "active", as well as to "standby" terminal(s), such as data servers / routers etc. at the customer premises. The equipment is “Fail-Safe” and never becomes a point-of-failure, even in power down condition

Data Sheet T1 Protection (Failover) Switch

DS3 Protection (Failover) Switch

DS3 Fail-Over (DS3 Protection) Switch allows the user to connect a single DS3 line from the telephone company to an "active", as well as to a "standby" DS3 terminal, such as data server / router etc., at the customer premises. The equipment is “Fail-Safe” and never becomes a point-of-failure, even in power down condition.

Data Sheet DS3 Protection (Failover) Switch

E1, 16 Port DACS

16 E1 Port Digital Access Cross Connect Switch offers full cross connect functionality to cross connect, and/or aggregate DS-0s, "n"x64Kbps data channels and fractional E1 channels to full E1 channels.

Data Sheet E1 16 Port DACS

T1, 16 Port DACS

16 T1 Port Digital Access Cross Connect Switch offers full cross connect functionality to cross connect, and/or aggregate DS-0s, fractional T1 channels to full T1 channels.

Data Sheet T1 16 Port DACS

E1, 80 Port DACS

80 E1 DXC / E1 DACS - Upto 80 E1, 160Mbps Digital Access Cross Connect is a modular switch which may be scaled from 8 E1 Ports to up to 80 E1 Ports. The DXC offers upto 160Mbps, 80 E1 fully non-blocking cross-connect at 64Kbps (DS-0) level (2480 DS-0 – any to any time-slot cross-connect), scalable from 8 E1 Ports to 80 E1 Ports, 1+1 Control Card Processor Redundancy, 1+1 Cross-Connect / TSI Redundancy, 1+1 Timing (Synchronization Clock) Redundancy, 1+1 -48V DC Power Supply Redundancy.

Data Sheet E1, 80 Port DACS

T1, 80 Port DACS

80 T1 DXC / T1 DACS - Upto 80 T1, 120Mbps Digital Access Cross Connect Switch, is a modular switch that may be scaled from 8 T1 Ports to up to 80 T1 Ports. The VCL-MX Version 6, T1 DACS (T1 DXC) offers full cross-connect functionality to cross-connect between 64Kbps time-slots (DS-0s), “n"x64 Kbps consecutive DS-0s and Fractional T1 channels to full T1 channels.

Data Sheet T1, 80 Port DACS

E1, 64 Ports Electronic Patch Panel

64 E1 port intelligent (Manageable) Electronic Patch Panel allows the user to cross-connect any E1 port to any to any E1 ports, electronically, without having to use any external patch-cords or loose hanging wires. The E1 64 port electronic patch panel also provides the user with the capability to uni-directionally broadcast E1 inputs to multiple E1 destinations.

Data Sheet E1, 64 Ports Electronic Patch Panel

T1, 64 Ports Electronic Patch Panel

64 T1 port intelligent (Manageable) Electronic Patch Panel allows the user to cross-connect any T1 port to any to any T1 ports, electronically, without having to use any external patch-cords or loose hanging wires. The T1 64 port electronic patch panel also provides the user with the capability to uni-directionally broadcast T1 inputs to multiple T1 destinations

Data Sheet T1, 64 Ports Electronic Patch Panel

E1 to T1 Data converters - 16 Ports

16 Port T1/E1 (or E1/T1) converter solutions offers data (frame) and line-code conversion between an 8 x T1 interfaces and an 8 x E1 interfaces, at DS-0 (64 Kbps time-slot) level.

Data Sheet E1 to T1 Data converters

VCL-PG, 16/32E1 Packet Groomer

Valiant's ‘VCL-PG, E1 Packet Groomer’ may be used to groom up to 16 / 32 x E1 channels and convert their payload to RFC 5086, RFC 5087 and RFC 4553 compliant Ethernet Packets.

The ‘VCL-PG, E1 Packet Groomer is equipped with a highly reliable clock recovery mechanism for low jitter and wander control, even under variable network conditions.

The 16/32 x E1 Port ‘VCL-PG, E1 Packet Groomer’ provides 4x Gigabit combo Ethernet ports for Ethernet link redundancy, and QoS by implementing 802.1Q based VLAN, Differentiated Services (Diffserv/DSCP), Port based Priority and 802.1p packet priority classification protocols for network optimization. Port mirroring is also available so that the copy of same data may be output to duplicate servers for “Server” redundancy.

Data Sheet VCL-PG, 16/32E1 Packet Groomer

STM-1 Monitoring Groomer

VCL-STM-1 Monitoring Groomer is a cost-effective monitoring and grooming equipment which may be used to "non-intrusively" monitor "bi-directional" STM-1 links through an 80:20 optical splitter patch panel and allow the user to select 64Kbps time-slots and groom them to E1 output ports, which may be then connected to E1 probes, E1 signalling analysers and billing servers etc.

Data Sheet STM-1 Monitoring Groomer

E1 - 16 E1 Port Groomer

Provides upto 8 E1 links (16 E1 Ports) plus 4 additional E1 ports (Normal-Z) to connect to the measurement probe, billing servers etc.

Data Sheet 16 E1 Port Groomer

E1 - 32 Port Plus - E1 Groomer

Provides upto 16 E1 links (32 E1 Hi-z Ports) plus 4 additional E1 ports (Normal-Z) to connect to the measurement probe, billing servers etc.

Data Sheet 32 Port Plus, E1 Groomer

T1 - 32 Port Plus - T1 Groomer

Provides upto 16 T1 links (32 T1 Hi-z Ports) plus 4 additional T1 ports (Normal-Z) to connect to the measurement probe, billing servers etc.

Data Sheet 32 Port Plus, T1 Groomer

E1 - 64 Port Plus - E1 Groomer

Provides upto 32 E1 links (64 E1 Hi-z Ports) plus 16 additional E1 ports (Normal-Z) to connect to the measurement probe, billing servers etc. Available with -20dBsx (0.3Volt Pulse) E1 signal sensitivity. Also available with -30dBsx (0.1 Volt Pulse) and -40dBsx (0.03 Volt Pulse) E1 signal sensitivity.

Data Sheet 64 Port Plus, E1 Groomer

T1 - 64 Port Plus - T1 Groomer

Provides upto 32 T1 links (64 T1 Hi-z Ports) plus 16 additional T1 ports (Normal-Z) to connect to the measurement probe, billing servers etc. Available with -20dBsx (0.3Volt Pulse) T1 signal sensitivity. Also available with -30dBsx (0.1 Volt Pulse) and -40dBsx (0.03 Volt Pulse) T1 signal sensitivity.

Data Sheet 64 Port Plus, T1 Groomer

64 Port E1 HSL (High Speed Signaling Link) Monitoring Groomer

64 Port E1 HSL (High Speed Signalling Link) Monitoring Groomer for "non-intrusive" monitoring application for monitoring of upto 32, "live" HSL E1 (High Speed Signalling Link) traffic links, bi-directionally (i.e. in both transmit and receive directions).

Data Sheet 64 Port E1 HSL Monitoring Groomer

64 Port T1 HSL (High Speed Signaling Link) Monitoring Groomer

64 Port T1 HSL (High Speed Signalling Link) Monitoring Groomer for "non-intrusive" monitoring application for monitoring of upto 32, "live" HSL T1 (High Speed Signalling Link) traffic links, bi-directionally (i.e. in both transmit and receive directions).

Data Sheet 64 Port T1 HSL Monitoring Groomer

E1 Echo Canceller (1 x E1)

E1 (1 x E1) Echo Canceller in 1U high, 19 Inch Rack mount shelf, with telnet. 64ms Bi-Directional / 128ms. Uni-Directional - user selectable.

Data Sheet E1 Echo Canceller

E1 Echo Cancellers with Voice Quality Enhancement (VQE)

128ms Bi-Directional compact 8 x E1 Echo Canceller with Voice Quality Enhancement (VQE) features in a 19-inch, 1U (44mm height) chassis, with echo-tail programmable from 0ms. to 896ms. Cancel echo at near-end and far-end with single installation.

Data Sheet E1 Echo Cancellers with Voice Quality Enhancement

T1 Echo Canceller (1 x T1)

T1 (1 x T1) Echo Canceller in 1U high, 19 Inch Rack mount shelf, with telnet. 64ms Bi-Directional / 128ms. Uni-Directional - user selectable.

Data Sheet T1 Echo Canceller

T1 Echo Cancellers with Voice Quality Enhancement (VQE)

128ms Bi-Directional compact 8 x E1 Echo Canceller with Voice Quality Enhancement (VQE) features in a 19-inch, 1U (44mm height) chassis, with echo-tail programmable from 0ms. to 896ms. Cancel echo at near-end and far-end with single installation.

Data Sheet T1 Echo Cancellers with Voice Quality Enhancement

DS3 Echo Cancellers with Voice Quality Enhancement (VQE)

Industry's most compact DS3 Echo Canceller and Voice Quality Enhancement (VQE) solution with echo tail programmable feature from 0 ms. to 896 ms. Echo cancellation on each channel is 128 ms. Bi-directional (near-end and far-end) echo cancellation.

Data Sheet DS3 Echo Cancellers with Voice Quality Enhancement

Electronic Patch Panels, Hi-z Non-Intrusive Monitoring Panels and Splitters

E1, 64 Ports Electronic Patch Panel

The 64 E1 Ports Intelligent Electronic Patch Panel allows the user to cross-connect any E1 port to any / multiple E1 ports, electronically, without having to use any external patch-cords or loosely hanging wires. The E1 electronic patch panel also provides the user with the capability to uni-directionally broadcast one or more E1 inputs to multiple E1 destinations.

Data Sheet Electronic Patch Panels

T1, 64 Ports Electronic Patch Panel

The 64 T1 Ports Intelligent Electronic Patch Panel allows the user to cross-connect any T1 port to any / multiple T1 ports, electronically, without having to use any external patch-cords or loosely hanging wires. The T1 electronic patch panel also provides the user with the capability to uni-directionally broadcast one or more T1 inputs to multiple T1 destinations.

Data Sheet 64 Ports Electronic Patch Panel

E1, 120 Ohms Monitoring Patch Panel

E1, 120 Ohms, 16 Port High Impedance (Hi-Z) Non-Intrusive Monitoring Patch Panel (120 Ohms – Version) used for E1 Patching and Monitoring Applications.

Data Sheet 120 Ohms Monitoring Patch Panel

T1, 100 Ohms Patch Panel

T1, 100 Ohms, 16 Port High Impedance (Hi-Z) Non-Intrusive Monitoring Patch Panel (120 Ohms – Version) used for T1 Patching and Monitoring Applications.

Data Sheet 100 Ohms Patch Panel

E1, 75 Ohms Monitoring Patch Panel

75 Ohms Patch-Panel for E1 Non-Intrusive Monitoring Application. 75 Ohms Patch Panel connects to live E1 traffic for Hi-z (non-intrusive) monitoring application.

Data Sheet 75 Ohms Monitoring Patch Panel

E1 Splitter Patch Panel

16 x E1, 120 Ohms Splitter Patch Panel

Data Sheet E1 Splitter Patch Panel

T1 Splitter Patch Panel

16 x T1, 100 Ohms Splitter Patch Panel

Data Sheet T1 Splitter Patch Panel

E1 120 Ohms (RJ-45) to 75 Ohms Converters

16 E1 G.703, 120 Ohms (RJ45) to E1 75 Ohms (BNC Female) Converter Balun Panel

16 E1, G.703 balun panel with 120 Ohms (RJ45) to E1, 75 Ohms (BNC Female Connector) converter panel, may be used to convert up to 16, E1, 120 Ohms balanced (RJ45) Interfaces to E1, 75 Ohms un-balanced (BNC Female Connector) Interfaces. 19 Inch Rack Mount.

Data Sheet E1 120 Ohms to 75 Ohms Converters

16 E1, G.703, 120 Ohms (RJ45) to E1, 75 Ohms (1.6 / 5.6 Female Connector) Converter Balun Panel

16 E1, G.703 balun panel with 120 Ohms (RJ45) to E1, 75 Ohms (1.6 / 5.6 Female Connector) converter panel, may be used to convert up to 16, E1, 120 Ohms (RJ45) Interfaces to E1, 75 Ohms (1.6 / 5.6 Female Connector) Interfaces. 19 Inch Rack Mount.

Data Sheet Converter

16 E1, G.703, 120 Ohms (RJ45) to E1, 75 Ohms (BT43 Male Connector) Converter Balun Panel

16 E1, G.703 balun panel with 120 Ohms (RJ45) to E1, 75 Ohms (BT43 Male Connector) converter panel, may be used to convert up to 16, E1, 120 Ohms (RJ45) Interfaces to E1, 75 Ohms (BT43 Male Connector) Interfaces. 19 Inch Rack Mount.

Data Sheet Converter

16 E1, G.703, 120 Ohms (RJ45) to E1, 75 Ohms (M4 Female Connector) Converter Balun Panel

16 E1, G.703 balun panel with 120 Ohms (RJ45) to E1, 75 Ohms (M4 Female Connector) converter panel, may be used to convert up to 16, E1, 120 Ohms (RJ45) Interfaces to E1, 75 Ohms (M4 Female Connector) Interfaces. 19 Inch Rack Mount.

Data Sheet Converter

16 E1, G.703, 120 Ohms (RJ45) to E1, 75 Ohms (M4 Male Connector) Converter Balun Panel

16 E1, G.703 balun panel with 120 Ohms (RJ45) to E1, 75 Ohms (M4 Female Connector) converter panel, may be used to convert up to 16, E1, 120 Ohms (RJ45) Interfaces to E1, 75 Ohms (M4 Female Connector) Interfaces. 19 Inch Rack Mount.

Data Sheet Converter

Dual Balun (Shielded) 2 x BNC (F) (75 Ohms) to RJ-45 (F) 120 Ohms Converter

Dual Balun (Shielded) 2 x BNC (F) (75 Ohms) to RJ-45 (F) 120 Ohms Converter

Data Sheet Converter

Power Supply AC to DC Converters and DC to DC Converters

DC to DC Converter - 48V DC to 24V DC (19 Inch Rack Mount Version)

DC to DC Converter - 48V DC (range DC 36-76) to 24V DC converter. This DC to DC converter may be used to convert 48V DC (range 36V DC to 76V DC) Main Input Voltage to 24V DC output voltage. Available with 4.2 Amps (100 Watts) with 4 fuse protected outputs. 19 Inch Rack Mount Version.

Data Sheet DC to DC Converter

AC to DC Converter - Universal AC Mains to 48V DC converter (Desktop Version)

AC to DC converter may be used to convert 85V AC-264V AC, 47Hz-63Hz AC Mains Input Voltage to 48V DC output voltage. This AC to DC converter may be also used to convert 120V DC - 370V DC Input Voltage to 48V DC Output Voltage. Available with 1.1 Amps (50 Watts), 1 fuse protected Output. Desktop Version.

Data Sheet AC to DC Converter

AC to DC Converter - Universal AC Mains to -48V DC converter (Desktop Version)

AC to DC converter may be used to convert 85V AC-264V AC, 47Hz-63Hz AC Mains Input Voltage to 48V DC output voltage. This AC to DC converter may be also used to convert 120V DC - 370V DC Input Voltage to 48V DC Output Voltage. Available with 3.2 Amps (150 Watts), 1 fuse protected Output. Desktop Version.

Data Sheet AC to DC Converter

AC to DC Converter - Universal AC Mains to 24V DC converter. (Desktop Version)

AC to DC converter may be used to convert 85V AC-264 V AC, 47Hz-63Hz AC Mains Input Voltage to 24V DC output voltage. It may be also used to convert 120V DC - 370V DC Input Voltage to 24V DC Output Voltage. Available with 6.3 Amps (150 Watts), 1 fuse protected Output. Desktop Version.

Data Sheet AC to DC Converter

AC to DC Converter - Universal AC Mains to 24VDC. (19 Inch Rack Mount Version)

AC to DC converter may be used to convert 85V AC-264V AC, 47Hz-63Hz AC Mains Input Voltage to 24 V DC output voltage. It may be also used to convert 120 V DC - 370 V DC Input Voltage to 24 V DC Output Voltage. Available with 6.3 Amps (150 Watts), 4 fuse protected outputs. 19 Inch Rack Mount Version.

Data Sheet AC to DC Converter

AC to DC Converter - Universal AC Mains to 48V DC converter. 3.2 Amps 150 Watts 4 fuse protected outputs. (19 Inch Rack Mount Version)

AC to DC converter may be used to convert 85V AC-264V AC, 47Hz-63Hz AC Mains Input Voltage to 48V DC output voltage. It may be also used to convert 120V DC - 370V DC Input Voltage to 48V DC Output Voltage. Available with 3.2 Amps (150 Watts). 4 fuse protected outputs. 19 Inch Rack Mount Version.

Data Sheet AC to DC Converter

VCL-MX Version 6 - 80 E1 Voice and Data Multiplexer

  • 160Mbps, 80 E1 fully non-blocking cross-connect at 64Kbps (DS-0) level (2480 DS-0 – any to any time-slot cross-connect)
  • Multi-service platform – may be used to provide a wide variety of voice and data services from single chassis
  • 1+1 E1 Link Protection / E1 Port Redundancy (8 E1's per card)
  • 1+1 Control Card Processor Redundancy
  • 1+1 Cross-Connect / TSI Redundancy
  • 1+1 Timing (Synchronization Clock) Redundancy. User selectable synchronization priority
  • 1+1 48V DC Power Supply Redundancy (Dual Power Input – allows the equipment to be powered from two separate sources
  • Provides 4 Binary (110VDC / 220VDC) Teleprotection Commands interface for Distance Protection
  • Provides IEEE C37.94 Optical Teleprotection ports for providing Distance / Differential Protection
  • Supports Automated Meter Data Reading (AMR) application with RS232 / RS485 interfaces
  • Extending Analog Breaker Status Monitoring to Audio / Visual Annunciator Panel at Remote Location.
Data Sheet VCL-MX Version 6

E1 PRI ISDN (Q.931) Multiplexer with FXS interfaces

Provides an E1 PRI (Q.931) ISDN Interface on the E1 (digital / telco) side and provide 30, FXS Ports on the customer side to connect to 30 telephone sets (or to an analog PABX). The analog lines from the multiplexer provide the telephone sets on the customer side with dial-tone, ring voltage and line current.

Data Sheet E1 PRI ISDN (Q.931) Multiplexer with FXS interfaces

E3 PDH (2/34Mbps) Multiplexer

E3, 34Mbps multiplexer multiplexes 16, 2Mbps E1 electrical tributaries into one 34Mbps electrical stream conforming to all applicable G.703, G.823 and G.831 ITU-T recommendations.

Data Sheet E3 PDH (2/34Mbps) Multiplexer

E1 PCM Multiplexer - 2Mbps Voice & Data Multiplexer

E1, 2Mbps 30 Channel PCM Multiplexer / E1 Channel Bank provides a full range of Voice - FXO, FXS, E&M, Hotline and Digital Data interfaces. Deployment on copper pairs (E1 or HDSL Transport), optical fiber cables, digital microwave radio or digital satellite links.

Data Sheet E1 Multiplexer

VCL-3010, RS232 to Ethernet Point-to-Point Converter

VCL-3010, RS232 to Ethernet Converter is a ruggedized and robust, sub-station-hardened protocol converter which shall convert Serial RS232 data to Ethernet data. VCL-3010 supports point-to-point application.

RS232 to Ethernet ConverterData Sheet (PDF)

VCL-3020, RS232 to Ethernet Point-to-Multi-Point Converter

VCL-3020, RS232 to Ethernet Converter is a ruggedized and robust, sub-station-hardened protocol converter which shall convert Serial RS232 data to Ethernet data. VCL-3020 supports point-to-point and point-to-multi-point conference application in which one VCL-3020 can communicate up to 5 x VCL-3010 / Slave devices at a time.

RS232 to Ethernet ConverterData Sheet (PDF)

VCL-3030, IEC 60870-5-101 to 60870-5-104 / MODBUS to Ethernet Protocol Converter

VCL-3030, IEC 60870-5-101 to 60870-5-104 / MODBUS to Ethernet Protocol Converter is a ruggedized and robust, sub-station-hardened protocol converter which shall convert Serial -101 to Ethernet -104 and Serial MODBUS to Ethernet data.

RS232 to Ethernet ConverterData Sheet (PDF)

VCL-3040, Quad RS232 to RS485 Converter

VCL-3040, Quad RS232 to RS485 Converter is a ruggedized, robust, sub-station-hardened protocol converter which converts the Serial RS232 data in to RS485 data and vice versa. VCL-3040 is a bi-directional serial ethernet interface converter which enables the interconnectivity between Ethernet and serial RS232 / RS485 interfaces.

RS232 to Ethernet ConverterData Sheet (PDF)

Time Distribution Solutions

VCL-2486-G
16 x 1 PPS + NMEA, GPS Receiver

The VCL-2486-G, 16 x 1 PPS + NMEA, GPS Receiver, Time Distribution Unit is designed to provide up to 16 outputs of Pulse and / or NMEA-0183 and / or IRIG-B (mix and match) that is locked to a GPS / GNSS Reference to provide time synchronization to private networks such as Railways and Metro (ticketing and platforms) networks, Airports and Air-Traffic Control facilities, Electric Sub-Stations, Power Distribution and Transmission companies, Oil and Gas Utilities, ISPs and Cable TV networks as well as to Campus networks.

Data Sheet VCL-2486-G

VCL-2486-M
Pulse + NMEA Multiplexer

The VCL-2486-M 1:16 Pulse + NMEA Multiplexer is a compact and cost-effective solution to provide up to 16 Pulse; NMEA-0183 outputs. VCL-2486-M 1:16 Pulse + NMEA Multiplexer takes one pulse (1PPS) and one NMEA-0183 as inputs to provide up to 16 pulse (1PPS) outputs; or 8 Pulse + 8 NMEA outputs.

Data Sheet VCL-2486-M

VCL-2486-I
IRIG-B Distribution Unit

The VCL-2486-I IRIG-B Distribution Unit is a compact and cost-effective solution to provide up to 16 IRIG-B outputs. VCL-2486-I IRIG-B Distribution Unit takes a single IRIG-B input to provide up to 16 IRIG-B outputs. The VCL-2486-I IRIG-B Distribution Unit used to multiply 1 x IRIG-B to provide 16 x IRIG-B outputs.

Data Sheet VCL-2486-I

VCL-2728
Optical to Pulse / IRIG-B Converter

The Optical to Pulse / IRIG-B Converter is a compact and cost-effective solution to convert Optical pulse upto 4 x IRIG-B / pulse (1PPS) Outputs.

Data Sheet VCL-2486-R

VCL-3045
NTP to 4 x IRIG-B Converter

VCL-3045, NTP to IRIG-B Converter is a compact DIN-Rail mounted chassis that is synchronized by an NTP Server which can be used to provide upto 4 x IRIG-B outputs for time-of-day synchronization.

Data Sheet ntp-irig-b-converter

VCL-2786
NTP to 16 x IRIG-B Converter

VCL-2786, NTP to 16 x IRIG-B Converter is a 19-inch, 1U high rack mountable chassis that is synchronized by an NTP Server which can be used to provide upto 16 x IRIG-B outputs for time-of-day synchronization.

Data Sheet 16 x ntp-irig-b-converter

VCL-2103:High Performance NTP Sub-Master Clock
VCL-2103 – NTP Sub-Master Clock

Valiant’s VCL-2103, SUB-MASTER CLOCK is a high performance, “intermediate” time synchronization source which may be referenced to multiple Primary GPS Reference (Master) Clock(s) using NTP protocol to provide "Time-of-Day" synchronization to client-side NTP/SNTP Slave devices in the network. Applications of Valiant’s NTP Sub-Master Clock include all such installations where network segregation is considered to be essential to isolate sections of the network that are considered to be less secure that require added cyber-security.

Valiant’s NTP Sub-Master Clock emulates the “CLOCK-IN-THE-MIDDLE” which installs between a secure (client) network(s) and an un-secured (public) network to allow the client-side terminals to securely synchronize to the public NTP servers with comprehensive network security. The NTP Sub-Master Clock incorporates a firewall that assistes in securing the “Client Network” from hostile attacks and intrusions that can originate from an un-secured, or less-secure sections of the network. The VCL-2103 Sub-Master Clock mediates between the Primary GPS Reference (Master) Clocks and the Slave NTP/ SNTP devices, such as Time-of-Day Display Clocks in a LAN, to effectively isolate the GPS Primary Reference Clock Source from the NTP/SNTP Slave devices and provide NTP/SNTP time-of-day synchronization with better than 0.5 millisecond accuracy.

Data SheetVCL-2103 – NTP Sub-Master Clock

VCL-W-KLOX High Reliability Time Display Unit
VCL-2106 – Time Display units

Valiant’s VCL-W-KLOX is a high precision digital clock that offers un-matched reliability, dependability and security that is not commonly found in similar competing products. The VCL-W-KLOX is a temperature hardened design with industrial grade EMI, EMC and surge protection provided on all interfaces making it suitable for installing in the harshest industrial or commercial environments that may include sub-stations, mines, defense installations, airports, railway, metro stations as well as industrial establishments.

The VCL-W-KLOX can be installed in a network to synchronize with multiple “Reference (Master) Clocks” to provide 1+1 or n+1 source redundancy in a NTP/SNTP time synchronization network. The VCL-W-KLOX is a highly accurate time display unit that is equipped with an internal TCXO which provides better than 0.1 second / day hold-over accuracy in the event of loss synchronization with its “Reference Time Source(s)”.

High precision NTP Display Clocks available in HH:MM or HH:MM:SS format. 2-inch, 4-inch and 8-inch LED Digit Size and 110~240V, 50/60Hz AC, or 24-72VDC power supply options.

Data SheetVCL-2106 – Time Display units

2705
GPS Receiver with IRIG-B

The VCL-2705 GPS Receiver and Time Distribution Unit is a low cost and high-performance GPS Receiver with multiple IRIG-B outputs which provides sub-microsecond accuracy. The VCL-2705 is designed to provide 1 x IRIG-B (BNC) output, 1 x IRIG-B RS-485 (differential pair with multi-drop capability to support up to 16 RTUs) and 1 x RS-232 (twisted pair) output. Unit also support dual power supply input for redundancy and one external dry relay alarm contact.

The relay has a rating of 5 Amps (amperes) and a maximum 250V DC, which can be connected to an external alarm such as a piezoelectric buzzer or an DC powered (LED) lamp and can be wired up for either NO or NC contact.

Data SheetVCL-2705