VCL Products > GPS / GNSS Time Servers
GPS / GNSS / NavIC NTP Time Servers
VCL offers a wide range of NTP Time Servers with ITU-T G.811 Primary Reference Clock for precise time synchronization across critical infrastructure such as utilities, transport, airports, defense, ISPs, and secure private networks. These servers feature integrated multi-band GNSS receivers that lock to GPS/GNSS/NavIC satellites with anti-jamming and anti-spoofing protection. Unlike public NTP sources that expose networks to cyber threats, VCL’s GPS/GNSS-based Stratum 1 servers ensure secure, reliable, and isolated time synchronization for 3G/4G/5G providers and private organizations.
Summary Flyer (PDF)

VCL-3048: NTP Time Server, IRIG-B |
||
---|---|---|
Inputs: | GPS/GNSS | |
Outputs: | NTP, 1PPS, IRIG-B (Unmodulated BNC, RS-232, RS-485 / RS-422) |
|
Power Supply: | 12V DC, 24V DC, 48V DC | |
Service Capacity: | Suitable for servicing up to 3000 NTP / SNTP requests per second. |
|
Read More... | Data Sheet (PDF) |

VCL-2156: NTP, PRC (ITU-T G.811), IRIG-B DCLS & AM |
||
---|---|---|
Inputs: | GPS/GNSS/NavIC, 1PPS and NTP | |
Outputs: | NTP, 2.048MHz, 10MHz, 1PPM/1PPH, 1PPS, 1PPS Adj, ToD NMEA 0183, IRIG-B (Unmodulated and Modulated) | |
Power Supply: | 24V DC, 48V DC, 110-220V DC, 110-240V AC, 1+1 Redundant PSU | |
Service Capacity: | Suitable for servicing up to 7500 NTP / SNTP requests per second. | |
Read More... | Data Sheet (PDF) |


VCL-2156: GigE NTP Server |
||
---|---|---|
Inputs: | GPS/GNSS (1+1) | |
Outputs: | 4 x Gigabit NTP ( RJ45), 1 x Gigabit PTP (RJ45) |
|
Power Supply: | 24V DC, 48V DC, 110-220V DC, 110-240V AC, 50/60 Hz |
|
Read More... | Data Sheet (PDF) |
VCL-2156-EXT, NTP Time Server, GPS / GNSS / NavIC | ||
---|---|---|
Inputs: | GPS / GNSS / NavIC, NTP and 1PPS | |
Outputs: | 1PPS, 1PPS Adj., 2.048MHz, 10MHz, 1PPM, IRIG-B (Modulated / Unmodulated - BNC, Unmodulated - RS232, RS485, RJ45, ST - Optical), ToD, 4 User selectable time and frequency output modules. | |
Power Supply: | 1+1 Power Supply option, 24V DC, 48V DC, 110-220V DC, 110-240V AC, 50/60 Hz | |
Read More... | Data Sheet (PDF) |


VCL-2145-D: GPS/GNSS (1+1), PRC (G.811), PTP, NTP, IRIG-B |
||
---|---|---|
Inputs: | GPS/GNSS (1+1), 10MHz, 2.048MHz, 2.048Mbit/s (E1) | |
Outputs: | NTP, PTP, 1.544Mbit/s (T1) / 2.048Mbit/s (E1), 2.048MHz, 10MHz, 1PPS, 1PPM, IRIG-B, ToD NMEA-0183 | |
Power Supply: | 24V DC, 48V DC, 110-220V DC, 110-240V AC, 1+1 Redundant PSU | |
Service Capacity: | Suitable for servicing up to 10,000 NTP / SNTP requests per second. | |
Read More... | Data Sheet (PDF) |
VCL-2145-DE: GPS/GNSS (1+1), PRC (G.811), PTP, NTP, IRIG-B | ||
---|---|---|
Inputs: | GPS/GNSS (1+1), 10MHz, 2.048MHz, 2.048Mbit/s (E1) | |
Outputs: | NTP, PTP, 1.544Mbit/s (T1) / 2.048Mbit/s (E1), 2.048MHz, 10MHz, 1PPS, 1PPM, IRIG-B, ToD NMEA-0183 | |
Power Supply: | 24V DC, 48V DC, 110-220V DC, 110-240V AC, 1+1 Redundant PSU | |
Service Capacity: | Suitable for servicing up to 8900 NTP / SNTP requests per second. | |
Read More... | Data Sheet (PDF) |


VCL-Mega: NTP Time Server | ||
---|---|---|
Inputs: | GPS/GNSS, 1PPS | |
Outputs: | 16 x 1G/10G NTP Outputs | |
Power Supply: | 110~240VAC, 1+1 Redundant Hot-swappable PSU | |
Service Capacity: | Suitable for servicing up to 1 Million NTP / SNTP requests per second. | |
Read More... | Data Sheet (PDF) |
VCL-2103: High Performance NTP Sub-Master Clock | ||
---|---|---|
Inputs: | 1 x 10/100/1000BaseT Ethernet NTP Input Port with automatic synchronization with multiple (redundant) NTP Server(s) | |
Outputs: | 4 x 10/100BaseT Ethernet NTP / SNTP Output Ports for slave device(s) | |
Power Supply: | 24V DC, 48V DC, 110V DC / 220V DC, 90V AC-240V AC, 50/60 Hz | |
Read More... | Data Sheet (PDF) |

Valiant Communications is an ISO 9001:2015, ISO 10001:2018, ISO 14001:2015, ISO 27001:2022, and ISO 45001:2018 certified equipment manufacturer.
Links
Networking
1+1 Ethernet Failover / AB Fallback Switch
Power Utilities
Teleprotection over E1, C37.94,
MPLS-TP, MPLS / IP, IEC-61850 GOOSE
IEEE C37.94 Line Differential Solutions
VCL-PMU-30, Phasor Measurement Unit (PMU)
Grid Islanding & WAMS Solutions
Cybersecurity
Network Isolation (Kill) Equipment
Data Storage
Time & Frequency Synchronization
GPS / GNSS, Primary Reference Clocks (G.811)
PTP IEEE-1588v2 Grandmaster, PTP Slave,
PTP Transparent Clock
Time Distribution, NTP, PTP, IRIG-B, 1PPS
RS-232 / RS-485
Frequency Distribution, 1PPS, 2.048MHz,
2.048Mbits, 1/5/10MHz, Optical
Power Converters
TDM & Legacy
SDH with MPLS-TP & SONET Multiplexers
E1 PDH & Digital Cross Connect
IP over TDM / Ethernet over TDM
TDM over IP / Ethernet / Packet / MPLS
E1 / T1, 1+1 Automatic Protection / Failover