Features and Highlights
- IEEE C37.94 compliant Multi-Mode optical fiber interface for transmission over short-reach multi-mode optical fiber link
- IEEE C37.94 modulation compliant Single-Mode optical fiber interface for transmission over long-reach, single-mode optical fiber link (≤ 40 KM, ≤ 80 KM, ≤ 120 KM, ≤ 150 KM, ≤ 180 KM), without optical repeaters.
- Unrivaled Speed, Security and Reliability
- Use in a Standalone, Point-To-Point Application
- Use as an integrated part of the VCL-MX Version 6 E1 Voice and Data Multiplexer solution over an SDH or PDH data network
- 1+1 Route / Path Protection when used as an integrated part of the VCL-MX Version 6 E1 Voice and Data Multiplexer solution over an SDH or PDH data network.
- Compact, standard 19-Inch Rack-mountable, 2U high chassis.
- Bi-directional Transmission of 8 command Inputs and 8 command outputs
- Full Duplex Operation
- Automatic loop test facility
- User programmable for Direct Tripping, Permissive Tripping and Blocking Protection Schemes
- IRIG-B / NTP Time Synchronization
- Compliant with IEC 60834-1 standards
- Available in 24V DC, 48V DC, 110V DC and 250V DC configurations.
- Available with 3 options:
- 8 Command Teleprotection Terminal
(8 Nos. Tx & Rx independent command inputs & outputs for providing interconnection with Protection Relays).
C37.94 Optical Interface, Single Mode 1310nm.
Available power options: 48V DC, 110V DC, 250V DC
- 8 Command Teleprotection Terminal
(8 Nos. Tx & Rx independent command inputs & outputs for providing interconnection with Protection Relays).
C37.94 Optical Interface, Multi-Mode 850nm.
Available power options: 48V DC, 110V DC, 250V DC
- 8 Command Teleprotection Terminal
(8 Nos. Tx & Rx independent command inputs & outputs for providing interconnection with Protection Relays).
C37.94 Optical Interface, Multi-Mode 1310nm.
Available power options: 48V DC, 110V DC, 250V DC
Flexibility and User Programmability
- User programmable command holding delay for error resistant command inputs
- User programmable command sampling rate for error resistant command transmission
- Less than 2ms command transfer time
- Less than 4ms relay operating time
- Less than 6ms back-to-back operating time (including relay operating time) in IEEE C37.94 Optical mode
Event and Alarm Logging
- Time-Stamped Alarm Logging
- Time-Stamped Event Logging.
Management and Monitoring
- RS232 serial, USB serial interfaces for local terminal access
- 10/100BaseT Ethernet Interface for remote access over an IP network
- Encrypted Password Protection
- Telnet - Remote access over IP links
- SSH - Secured remote access using Secure Shell Protocol over IP links
- SNMP Traps and NMS for real time remote monitoring and management over an IP network
- Automatic Link Test feature – link testing at user programmable periodical intervals
- Visual I/O status – LED Display.
Reliability
- Advanced Communication Protocols to ensure reliable transmission of commands
- Power Supply Immunity to withstand impulse surges and transients of up to 10,000 Volts
- High Quality Relays – withstands voltage 10 kV between coil and contacts (1.2 × 50 μþs)
- Maximum Switching Voltage: 400V AC or 300V DC
- Optoisolated Command Inputs
- Optoisolated Relay Outputs
- Relays - Mechanical: 10,000,000 operations min. (at 18,000 operations/hour).
Error Detection and Coding
- Line Code Violation Detection
- LOS Detection
- Block Command Encoding as per IEEE C37.94.
Applications
Application # 1: Teleprotection over IEEE C37.94 Optical Interface
Figure # 1 – Typical Point-to-point Application
Application # 2: Teleprotection over IEEE C37.94 Optical Interface in 1+1 Configuration
Figure # 2 – Typical Application over a IEEE C37.94 compliant optical link, as an integrated part of the
VCL-MX Version 6 - E1 Voice and Data Multiplexer solution over an SDH or PDH data network.
Application # 3: Typical Application over an IEEE C37.94 compliant optical link
Figure # 3 – Typical Application over an IEEE C37.94 compliant optical link, as an integrated
part of the E1 PDH Voice & Data Multiplexer solution over an SDH or PDH data network.