Features and Highlights
                                    
                                - IEEE C37.94 compliant Multi-Mode optical fiber interface for transmission over short-reach multi-mode optical fiber link
 
                                    - IEEE C37.94 modulation compliant Single-Mode optical fiber interface for transmission over long-reach, single-mode optical fiber link (≤ 40 KM, ≤ 80 KM, ≤ 120 KM,  ≤ 150 KM, ≤ 180 KM), without optical repeaters.
 
                                    - Unrivaled Speed, Security and Reliability
 
                                    - Use in a Standalone, Point-To-Point Application
 
                                    - Use as an integrated part of the VCL-MX Version 6 E1 Voice and Data Multiplexer solution over an SDH or PDH data network
                                     - 1+1 Route / Path Protection when used as an integrated part of the VCL-MX Version 6 E1 Voice and Data Multiplexer solution over an SDH or PDH data network.
 
                                    - Compact, standard 19-Inch Rack-mountable, 2U high chassis.
 
                                    - Bi-directional Transmission of 8 command Inputs and 8 command outputs
                                     
                                    - Full Duplex Operation
 
                                    - Automatic loop test facility
 
                                    - User programmable for Direct Tripping, Permissive Tripping and Blocking Protection Schemes
 
                                    - IRIG-B / NTP Time Synchronization
 
                                    - Compliant with IEC 60834-1 standards
 
                                    - Available in 24V DC, 48V DC, 110V DC and 250V DC configurations.
 
                                    - Available with 3 options:
 
                                    
                                    - 8 Command Teleprotection Terminal 
 
                                    (8 Nos. Tx & Rx independent command inputs & outputs for providing interconnection with Protection Relays).
                                    C37.94 Optical Interface, Single Mode 1310nm.
                                    Available power options: 48V DC, 110V DC, 250V DC
                                    
                                    - 8 Command Teleprotection Terminal
 
                                    (8 Nos. Tx & Rx independent command inputs & outputs for providing interconnection with Protection Relays).
                                    C37.94 Optical Interface, Multi-Mode 850nm.
                                    Available power options: 48V DC, 110V DC, 250V DC 
                                    
                                    - 8 Command Teleprotection Terminal
 
                                    (8 Nos. Tx & Rx independent command inputs & outputs for providing interconnection with Protection Relays).
                                    C37.94 Optical Interface, Multi-Mode 1310nm. 
                                    Available power options: 48V DC, 110V DC, 250V DC 
                                    
                                    Flexibility and User Programmability
                                    - User programmable command holding delay for error resistant command inputs
 
                                    - User programmable command sampling rate for error resistant command transmission
 
                                    - Less than 2ms command transfer time
 
                                    - Less than 4ms relay operating time
 
                                    - Less than 6ms back-to-back operating time (including relay operating time) in IEEE C37.94 Optical mode
 
                                    
                                    Event and Alarm Logging
                                    - Time-Stamped Alarm Logging
 
                                    - Time-Stamped Event Logging.
 
                                    
                                    Management and Monitoring
                                    - RS232 serial, USB serial interfaces for local terminal access
 
                                    - 10/100BaseT Ethernet Interface for remote access over an IP network
 
                                    - Encrypted Password Protection
 
                                    - Telnet - Remote access over IP links
 
                                    - SSH - Secured remote access using Secure Shell Protocol over IP links
 
                                    - SNMP Traps and NMS for real time remote monitoring and management over an IP network
 
                                    - Automatic Link Test feature – link testing at user programmable periodical intervals
 
                                    - Visual I/O status – LED Display.
 
                                    
                                    Reliability
                                    - Advanced Communication Protocols to ensure reliable transmission of commands
 
                                    - Power Supply Immunity to withstand impulse surges and transients of up to 10,000 Volts
 
                                    - High Quality Relays – withstands voltage 10 kV between coil and contacts (1.2 × 50 μþs)
 
                                    - Maximum Switching Voltage: 400V AC or 300V DC
 
                                    - Optoisolated Command Inputs
 
                                    - Optoisolated Relay Outputs
 
                                    - Relays - Mechanical: 10,000,000 operations min. (at 18,000 operations/hour).
 
                                    
                                    Error Detection and Coding
                                    - Line Code Violation Detection
 
                                    - LOS Detection
 
                                    - Block Command Encoding as per IEEE C37.94.
 
                      
                                 
                             
                         
                        
                        
                        
                        Applications
                        
                         Application # 1: Teleprotection over IEEE C37.94 Optical Interface
                        
                         
                        
                         Figure # 1 – Typical Point-to-point Application
                        
                         Application # 2: Teleprotection over IEEE C37.94 Optical Interface in 1+1 Configuration
                        
                         
                        
                        Figure # 2 – Typical Application over a IEEE C37.94 compliant optical link, as an integrated part of the 
                       VCL-MX Version 6 - E1 Voice and Data Multiplexer solution over an SDH or PDH data network.
                       
                        Application # 3: Typical Application over an IEEE C37.94 compliant optical link
                       
                        
                       
                       Figure # 3 – Typical Application over an IEEE C37.94 compliant optical link, as an integrated
                        part of the E1 PDH Voice & Data Multiplexer solution over an SDH or PDH data network.