Synchronization
- Timing Options - Internal Clock, Loop-Timed Clock, External Clock
- Synchronization Sources - Internal Clock, span clock timing derived from incoming HDB3 links (Loop-Timed), External Clock, 75 Ohms 2 MHz (TTL), 2.048 Mbps (BITS) Clock.
- Default Option - Internal Clock (Stratum 3)
Analog I/O Interface Card (Dry Relay Contacts)
This interface card provides 8 Analog I/Os which may be used to extend either Dry Relay Contacts (Relay Normally-Open or Relay Normally-Close) or operate switches remotely (using 2A Dry Relay Contacts) between any two multiplexers using a 64 Kbps time-slot. The Dry Relay Contacts are rated at maximum 2 Amps, 30 Volts DC.
Digital I/O Interface Card (Digital TTL Signal Transfer Card)
This interface card provides 8 digital I/Os which may be used to either extend digital I/O’s (logic high / low) signals between any two E1 Multiplexers or operate switches remotely (using logic high/low) signals between any two multiplexers. Drivers / Sense Logic operate using external voltage and ground references).
Universal Data Interface Card:
V.35 / V.36 / RS422 / V.11 / RS530 / X.21, DTE/DCE, "N" x 64Kbps Synchronous Data Interface, ONE Interface per Card - User Selectable Data Rate of "N" (1 thru 30) - DCE or DTE (User Configurable).